Technical system data · reviewed 08/2026

Reynaers · aluminum windows

EcoSystem 50
Compact, balanced system solution

A thermally insulated system with low installation depth and reduced visible profile heights. It combines compact construction with a balanced relationship between function, quality and economy.

  • System-specific performance data
  • Visible revision status
  • For architects and specifiers

Profile section

Explore functional zones
System overview
Profile section of the Reynaers EcoSystem 50 aluminum window system
01

Profile assembly

Published Uf value 1.60 W/(m²K)

Select the three markers to classify the profile assembly, glazing zone, seals and drainage.

Uw value

2.6 W/(m²·K)

Max. Height

2.200 mm

sash weight

120 kg

Security

RC2 Possible

Data status

reviewed 08/2026

System values; achievable performance and dimensions depend on opening type, glazing, hardware, profile combination and verified unit configuration.

01 · System performance

Published data in a transparent technical structure.

Every value remains assigned to its technical category, so thermal performance, dimensions, security, comfort and glazing can be reviewed without mixed marketing claims.

System data sheet

Reynaers EcoSystem 50

Revision 08/2026
PropertySystem valueCategory
Insulation
Thermal insulation – Uf1.6 W/(m²·K)Insulation
Thermal insulation – Uw2.6 W/(m²·K)Insulation
Basis of the Uw calculationFrame-sash combination with Ug 1.0 W/(m²·K), warm edge, element size 1.23 × 1.48 m, 92 mm view width and 24 mm glass.Insulation
Comfort
AirtightnessClass 4 (600 Pa)Comfort
WatertightnessClass 9A (600 Pa)Comfort
Wind load resistanceCategory C4 (1600 Pa)Comfort
Acoustics – Rw (C; Ctr)38 (−1; −2) dBComfort
Permanent functionClass 2 (10.000 cycles)Comfort
Security
Burglary resistanceRC2Security
Maximum Dimensions & Weights
Min. Sash height700 mmMaximum Dimensions & Weights
Max. Sash height2200 mmMaximum Dimensions & Weights
Max. sash weight120 kgMaximum Dimensions & Weights
Sightlines & profile depths
Frame sightline, inward-opening48 mmSightlines & profile depths
Sash sightline, inward-opening30 mmSightlines & profile depths
Combined frame/sash sightline, inward-opening86 mmSightlines & profile depths
Frame sightline, outward-opening21 mmSightlines & profile depths
Sash sightline, outward-opening73 mmSightlines & profile depths
Combined frame/sash sightline, outward-opening99.5 mmSightlines & profile depths
Profile depth, frame/sash50 / 59 mmSightlines & profile depths
Profile depth, outer frame/sash50 mmSightlines & profile depths
Glazing
Glass entry22 mmGlazing
Glazing methodDry or silicone glazing, interior or exterior, glazing beadGlazing
Glass thickness, sash4–32 mmGlazing

Values are taken from the system-specific data already maintained on this website. The binding result is produced from the actual unit configuration.

02 · Profile construction

From profile section to verified project planning.

Profiles, glazing, seals and hardware are treated as one system. This separates published values from the items that require project-specific verification.

01

System platform

profile-dependent frame depth or profile-dependent construction.

Planning: frame, sash, mullion and meeting stile
02

Glazing

Published range: 4–32 mm.

Planning: build-up, weight, size and spacer
03

Seals and drainage

Air: Class 4 (600 Pa) · Water: Class 9A (600 Pa).

Planning: exposure and drainage
04

Hardware and security

Burglary resistance: RC2.

Planning: opening type, weight and tested assembly

03 · Interactive tool

Estimate the whole-window U-factor with visible inputs and formula.

The calculator uses the published Uf input for the selected system, the glazing Ug value, the unit geometry and the spacer Ψ value.

Area-weighted preliminary calculation

Enter window data

Live calculation
System and geometry
Glazing and spacer
Preliminary whole-window U-factorReynaers EcoSystem 50
W/(m²K)
Calculating
Window area Aw
Frame area Af
Glass area Ag
Glass-edge length lg
Formula and calculation

Uw = (Af × Uf + Ag × Ug + lg × Ψg) ÷ Aw

Preliminary planning value. Mullions, transoms, divided lites, special geometry, actual profile combinations and applicable project standards must be included in the binding calculation.

04 · Planning resources

CAD, sections and specifications in one logical area.

Existing resources link directly to the relevant content. CAD details that are not yet public can be requested with the selected system already identified.

PDF

System data

Technical data overview

All currently stored performance values

Current data status · 08/2026
PDF

Downloads

Product brochures and documents

Available manufacturer resources

Website document library
CAD

DWG / DXF

Request a CAD section

Coordinate the appropriate configuration and revision

System preselected
TXT

Specification

Request specification text

System-specific text with project parameters

For architects and specifiers

05 · Planning knowledge

Answers organized around real specification questions.

Frequently asked questions remain readable on the page and are also provided as structured FAQ data.

Which values are binding for EcoSystem 50?

Only the values of the specifically engineered and verified unit configuration are binding, including profiles, size, opening type, glazing, hardware, anchoring and installation interface.

Which glazing can be used?

The published system range is 4–32 mm. A specific glass build-up also depends on size, weight, sash dimensions, hardware and structural verification.

Is RC2 automatically included?

No. A resistance class only applies to the tested assembly of profiles, hardware, glazing, anchoring and installation. The required class must be specified for the project.

How is the binding whole-window U-factor determined?

From the frame share, Uf value of the actual profile combination, glazing Ug value, glass-edge length, spacer Ψ value and, where applicable, mullions, transoms and special geometry.

From system value to project-specific unit

Enter dimensions. Select the build-up.
Receive a project value.

The configurator connects technical system data with drawings, glazing and a project quotation request.