Uw value
2.6 W/(m²·K)Reynaers · aluminum windows
EcoSystem 50
Compact, balanced system solution
A thermally insulated system with low installation depth and reduced visible profile heights. It combines compact construction with a balanced relationship between function, quality and economy.
- System-specific performance data
- Visible revision status
- For architects and specifiers
Profile section
Explore functional zones
Profile assembly
Published Uf value 1.60 W/(m²K)Select the three markers to classify the profile assembly, glazing zone, seals and drainage.
01 · System performance
Published data in a transparent technical structure.
Every value remains assigned to its technical category, so thermal performance, dimensions, security, comfort and glazing can be reviewed without mixed marketing claims.
Reynaers EcoSystem 50
| Property | System value | Category |
|---|---|---|
| Insulation | ||
| Thermal insulation – Uf | 1.6 W/(m²·K) | Insulation |
| Thermal insulation – Uw | 2.6 W/(m²·K) | Insulation |
| Basis of the Uw calculation | Frame-sash combination with Ug 1.0 W/(m²·K), warm edge, element size 1.23 × 1.48 m, 92 mm view width and 24 mm glass. | Insulation |
| Comfort | ||
| Airtightness | Class 4 (600 Pa) | Comfort |
| Watertightness | Class 9A (600 Pa) | Comfort |
| Wind load resistance | Category C4 (1600 Pa) | Comfort |
| Acoustics – Rw (C; Ctr) | 38 (−1; −2) dB | Comfort |
| Permanent function | Class 2 (10.000 cycles) | Comfort |
| Security | ||
| Burglary resistance | RC2 | Security |
| Maximum Dimensions & Weights | ||
| Min. Sash height | 700 mm | Maximum Dimensions & Weights |
| Max. Sash height | 2200 mm | Maximum Dimensions & Weights |
| Max. sash weight | 120 kg | Maximum Dimensions & Weights |
| Sightlines & profile depths | ||
| Frame sightline, inward-opening | 48 mm | Sightlines & profile depths |
| Sash sightline, inward-opening | 30 mm | Sightlines & profile depths |
| Combined frame/sash sightline, inward-opening | 86 mm | Sightlines & profile depths |
| Frame sightline, outward-opening | 21 mm | Sightlines & profile depths |
| Sash sightline, outward-opening | 73 mm | Sightlines & profile depths |
| Combined frame/sash sightline, outward-opening | 99.5 mm | Sightlines & profile depths |
| Profile depth, frame/sash | 50 / 59 mm | Sightlines & profile depths |
| Profile depth, outer frame/sash | 50 mm | Sightlines & profile depths |
| Glazing | ||
| Glass entry | 22 mm | Glazing |
| Glazing method | Dry or silicone glazing, interior or exterior, glazing bead | Glazing |
| Glass thickness, sash | 4–32 mm | Glazing |
Values are taken from the system-specific data already maintained on this website. The binding result is produced from the actual unit configuration.
02 · Profile construction
From profile section to verified project planning.
Profiles, glazing, seals and hardware are treated as one system. This separates published values from the items that require project-specific verification.
System platform
profile-dependent frame depth or profile-dependent construction.
Planning: frame, sash, mullion and meeting stileGlazing
Published range: 4–32 mm.
Planning: build-up, weight, size and spacerSeals and drainage
Air: Class 4 (600 Pa) · Water: Class 9A (600 Pa).
Planning: exposure and drainageHardware and security
Burglary resistance: RC2.
Planning: opening type, weight and tested assembly03 · Interactive tool
Estimate the whole-window U-factor with visible inputs and formula.
The calculator uses the published Uf input for the selected system, the glazing Ug value, the unit geometry and the spacer Ψ value.
- Window area Aw
- –
- Frame area Af
- –
- Glass area Ag
- –
- Glass-edge length lg
- –
Formula and calculation
Uw = (Af × Uf + Ag × Ug + lg × Ψg) ÷ Aw
Preliminary planning value. Mullions, transoms, divided lites, special geometry, actual profile combinations and applicable project standards must be included in the binding calculation.
04 · Planning resources
CAD, sections and specifications in one logical area.
Existing resources link directly to the relevant content. CAD details that are not yet public can be requested with the selected system already identified.
System data
Technical data overview
All currently stored performance values
Current data status · 08/2026Downloads
Product brochures and documents
Available manufacturer resources
Website document libraryDWG / DXF
Request a CAD section
Coordinate the appropriate configuration and revision
System preselectedSpecification
Request specification text
System-specific text with project parameters
For architects and specifiersNo resources match this filter.
05 · Planning knowledge
Answers organized around real specification questions.
Frequently asked questions remain readable on the page and are also provided as structured FAQ data.
Which values are binding for EcoSystem 50?
Only the values of the specifically engineered and verified unit configuration are binding, including profiles, size, opening type, glazing, hardware, anchoring and installation interface.
Which glazing can be used?
The published system range is 4–32 mm. A specific glass build-up also depends on size, weight, sash dimensions, hardware and structural verification.
Is RC2 automatically included?
No. A resistance class only applies to the tested assembly of profiles, hardware, glazing, anchoring and installation. The required class must be specified for the project.
How is the binding whole-window U-factor determined?
From the frame share, Uf value of the actual profile combination, glazing Ug value, glass-edge length, spacer Ψ value and, where applicable, mullions, transoms and special geometry.
From system value to project-specific unit
Enter dimensions. Select the build-up.
Receive a project value.
The configurator connects technical system data with drawings, glazing and a project quotation request.