Technical system data · reviewed 08/2026

Reynaers · aluminum windows

MasterLine 10
For passive-house and low-energy projects

A high-performance window solution for buildings with very high demands on energy efficiency, daylight and safety. Different design variants also allow concealed sashes.

  • System-specific performance data
  • Visible revision status
  • For architects and specifiers

Profile section

Explore functional zones
System overview
Profile section of the Reynaers MasterLine 10 aluminum window system
01

Profile assembly

Published Uf value 0.99 W/(m²K)

Select the three markers to classify the profile assembly, glazing zone, seals and drainage.

Uw value

0.8 W/(m²·K)

Max. Height

2.800 mm

sash weight

200 kg

Security

WK3 Possible

Data status

reviewed 08/2026

System values; achievable performance and dimensions depend on opening type, glazing, hardware, profile combination and verified unit configuration.

01 · System performance

Published data in a transparent technical structure.

Every value remains assigned to its technical category, so thermal performance, dimensions, security, comfort and glazing can be reviewed without mixed marketing claims.

System data sheet

Reynaers MasterLine 10

Revision 08/2026
PropertySystem valueCategory
Insulation
Thermal insulation – Uf0.99 W/(m²·K)Insulation
Thermal insulation – Uw0.8 W/(m²·K)Insulation
Basis of the Uw calculationFrame-sash combination with Ug 0.6 W/(m²·K), warm edge, element size 1.23 × 1.48 m, 104 mm sightline and 48 mm glass.Insulation
Comfort
AirtightnessClass 4 (600 Pa)Comfort
WatertightnessCategory E900 (900 Pa)Comfort
Wind load resistanceCategory C4 (1600 Pa)Comfort
Acoustics – Rw (C; Ctr)TuTi: 46 (−1; −4) dB; DC: 44 (−2; −4) dBComfort
Opening and closing resistanceClass 3Comfort
Security
Burglary resistanceWK2 to WK3Security
Maximum Dimensions & Weights
Sash height600–2800 mmMaximum Dimensions & Weights
Sash width550–1200 mmMaximum Dimensions & Weights
Max. sash weight200 kgMaximum Dimensions & Weights
Max. Glass weight800 kgMaximum Dimensions & Weights
Sightlines & profile depths
Minimum frame sightline, inward-opening60 mmSightlines & profile depths
Minimum sash sightline, inward-opening37 mmSightlines & profile depths
Minimum combined frame/sash sightline, inward-opening104 mmSightlines & profile depths
Minimum frame sightline, outward-opening27 mmSightlines & profile depths
Minimum sash sightline, outward-opening113 mmSightlines & profile depths
Minimum combined frame/sash sightline, outward-opening140 mmSightlines & profile depths
Minimum T-profile sightline87 mmSightlines & profile depths
Profile depth, frame97 mmSightlines & profile depths
Profile depth, sash107 mmSightlines & profile depths
Profile depth, outer frame/sash107 mmSightlines & profile depths
Glazing
Glass entry27 mmGlazing
Glazing methodDry or wet glazing, interior glazing or glazing beadGlazing
Glass thickness, frame/fixed glazing20–78 mmGlazing
Glass thickness, sash30–88 mmGlazing

Values are taken from the system-specific data already maintained on this website. The binding result is produced from the actual unit configuration.

02 · Profile construction

From profile section to verified project planning.

Profiles, glazing, seals and hardware are treated as one system. This separates published values from the items that require project-specific verification.

01

System platform

profile-dependent frame depth or profile-dependent construction.

Planning: frame, sash, mullion and meeting stile
02

Glazing

Published range: 20–78 mm.

Planning: build-up, weight, size and spacer
03

Seals and drainage

Air: Class 4 (600 Pa) · Water: Category E900 (900 Pa).

Planning: exposure and drainage
04

Hardware and security

Burglary resistance: WK2 to WK3.

Planning: opening type, weight and tested assembly

03 · Interactive tool

Estimate the whole-window U-factor with visible inputs and formula.

The calculator uses the published Uf input for the selected system, the glazing Ug value, the unit geometry and the spacer Ψ value.

Area-weighted preliminary calculation

Enter window data

Live calculation
System and geometry
Glazing and spacer
Preliminary whole-window U-factorReynaers MasterLine 10
W/(m²K)
Calculating
Window area Aw
Frame area Af
Glass area Ag
Glass-edge length lg
Formula and calculation

Uw = (Af × Uf + Ag × Ug + lg × Ψg) ÷ Aw

Preliminary planning value. Mullions, transoms, divided lites, special geometry, actual profile combinations and applicable project standards must be included in the binding calculation.

04 · Planning resources

CAD, sections and specifications in one logical area.

Existing resources link directly to the relevant content. CAD details that are not yet public can be requested with the selected system already identified.

PDF

System data

Technical data overview

All currently stored performance values

Current data status · 08/2026
PDF

Downloads

Product brochures and documents

Available manufacturer resources

Website document library
CAD

DWG / DXF

Request a CAD section

Coordinate the appropriate configuration and revision

System preselected
TXT

Specification

Request specification text

System-specific text with project parameters

For architects and specifiers

05 · Planning knowledge

Answers organized around real specification questions.

Frequently asked questions remain readable on the page and are also provided as structured FAQ data.

Which values are binding for MasterLine 10?

Only the values of the specifically engineered and verified unit configuration are binding, including profiles, size, opening type, glazing, hardware, anchoring and installation interface.

Which glazing can be used?

The published system range is 20–78 mm. A specific glass build-up also depends on size, weight, sash dimensions, hardware and structural verification.

Is WK2 to WK3 automatically included?

No. A resistance class only applies to the tested assembly of profiles, hardware, glazing, anchoring and installation. The required class must be specified for the project.

How is the binding whole-window U-factor determined?

From the frame share, Uf value of the actual profile combination, glazing Ug value, glass-edge length, spacer Ψ value and, where applicable, mullions, transoms and special geometry.

From system value to project-specific unit

Enter dimensions. Select the build-up.
Receive a project value.

The configurator connects technical system data with drawings, glazing and a project quotation request.