Technical system data · reviewed 08/2026

Schüco · aluminum windows

AWS 75.BS.SI+
Block window with an almost invisible sash and 66 mm exterior sightline

The block window system combines an externally concealed sash with a uniform appearance for fixed and opening elements. Despite its slim construction, it can reach passive-house performance and burglary resistance up to RC 2 — ideal for punched openings, ribbon windows and façade integration.

  • System-specific performance data
  • Visible revision status
  • For architects and specifiers

Profile section

Explore functional zones
System overview
Profile section of the Schüco AWS 75.BS.SI+ aluminum window system
01

Profile assembly

Published Uf value 1.30 W/(m²K)

Select the three markers to classify the profile assembly, glazing zone, seals and drainage.

Opening Uw value

0.78 W/(m²·K)

Noise protection

48 dB up to

Security

RC 2 up to

View outside

66 mm

Data status

reviewed 08/2026

System values; achievable performance and dimensions depend on opening type, glazing, hardware, profile combination and verified unit configuration.

01 · System performance

Published data in a transparent technical structure.

Every value remains assigned to its technical category, so thermal performance, dimensions, security, comfort and glazing can be reviewed without mixed marketing claims.

System data sheet

Schüco AWS 75.BS.SI+

Revision 08/2026
PropertySystem valueCategory
Insulation & Glazing
Frame Uf value≥ 1.3 W/(m²·K)Insulation & Glazing
Uw value, opening elementas low as 0.78 W/(m²·K)Insulation & Glazing
Uw value, fixed glazingas low as 0.71 W/(m²·K)Insulation & Glazing
Glass thickness max.54 mmInsulation & Glazing
Glazing constructionHigh-performance triple glazingInsulation & Glazing
Passive House-level performanceAvailable with project-specific configurationInsulation & Glazing
Comfort & Building physics
Sound insulationup to 48 dBComfort & Building physics
Air permeability (EN 12207)Class 4Comfort & Building physics
Watertightness (EN 12208)Class 9AComfort & Building physics
Wind load resistance (EN 12210)Class C5/B5Comfort & Building physics
Security
Burglary resistance (EN 1627)to RC 2Security
Dimensions & Weights
Sash width max.1500 mmDimensions & Weights
Sash height max.2,200 mmDimensions & Weights
Sash weight max.160 kgDimensions & Weights
Profile depth75 mmDimensions & Weights
Sightlines
Exterior sightline (concealed sash)66 mmSightlines
Minimum mullion sightline92 mmSightlines
Minimum meeting-stile sightline83 mmSightlines
Minimum transom sightline92 mmSightlines
Opening Types & Hardware
Manual, inward-openingtilt-and-turn, side-hung and fanlight tiltOpening Types & Hardware
Concealed hardware systemYes (AvanTec SimplySmart)Opening Types & Hardware
Opening angle180°Opening Types & Hardware
TipTronic compatibleYes (TipTronic SimplySmart)Opening Types & Hardware
Finishes
Surface finishingAnodizing or powder coatingFinishes
Color selectionFreely selectable, inside/outside different possibleFinishes
Construction & Design
Sash designCovered, 66 mm visible from the outsideConstruction & Design
OpticsConsistent exterior appearance across fixed and operable unitsConstruction & Design
Mullion designCorner, mullion, symmetrical and asymmetrical configurationsConstruction & Design
ApplicationsPunched openings, ribbon windows and curtain-wall insertsConstruction & Design
Product highlights
Nearly Invisible SashA 66 mm exterior sightline gives fixed and operable units a consistent appearance.Product highlights
Passive house insulationWith whole-window Uw values as low as 0.78 W/(m²·K), the system can support Passive House-level performance, subject to configuration.Product highlights
High noise protectionUp to 48 dB of sound insulation is also suitable for noise-exposed locations.Product highlights
Planning benefits
AvanTec SimplySmartThe concealed hardware system allows large sash weights and an opening angle of 180°.Planning benefits
TipTronic SimplySmartCompatible with electrically driven mechatronic fitting solutions.Planning benefits
Versatile mullion configurationsCorner and intermediate mullions, plus symmetrical and asymmetrical variants for a flexible facade grid.Planning benefits
Individual color designAnodizing or powder coating with free choice of color inside and outside.Planning benefits

Values are taken from the system-specific data already maintained on this website. The binding result is produced from the actual unit configuration.

02 · Profile construction

From profile section to verified project planning.

Profiles, glazing, seals and hardware are treated as one system. This separates published values from the items that require project-specific verification.

01

System platform

profile-dependent frame depth or profile-dependent construction.

Planning: frame, sash, mullion and meeting stile
02

Glazing

Published range: 54 mm.

Planning: build-up, weight, size and spacer
03

Seals and drainage

Air: Class 4 · Water: Class 9A.

Planning: exposure and drainage
04

Hardware and security

Burglary resistance: to RC 2.

Planning: opening type, weight and tested assembly

03 · Interactive tool

Estimate the whole-window U-factor with visible inputs and formula.

The calculator uses the published Uf input for the selected system, the glazing Ug value, the unit geometry and the spacer Ψ value.

Area-weighted preliminary calculation

Enter window data

Live calculation
System and geometry
Glazing and spacer
Preliminary whole-window U-factorSchüco AWS 75.BS.SI+
W/(m²K)
Calculating
Window area Aw
Frame area Af
Glass area Ag
Glass-edge length lg
Formula and calculation

Uw = (Af × Uf + Ag × Ug + lg × Ψg) ÷ Aw

Preliminary planning value. Mullions, transoms, divided lites, special geometry, actual profile combinations and applicable project standards must be included in the binding calculation.

04 · Planning resources

CAD, sections and specifications in one logical area.

Existing resources link directly to the relevant content. CAD details that are not yet public can be requested with the selected system already identified.

PDF

System data

Technical data overview

All currently stored performance values

Current data status · 08/2026
PDF

Downloads

Product brochures and documents

Available manufacturer resources

Website document library
CAD

DWG / DXF

Request a CAD section

Coordinate the appropriate configuration and revision

System preselected
TXT

Specification

Request specification text

System-specific text with project parameters

For architects and specifiers

05 · Planning knowledge

Answers organized around real specification questions.

Frequently asked questions remain readable on the page and are also provided as structured FAQ data.

Which values are binding for AWS 75.BS.SI+?

Only the values of the specifically engineered and verified unit configuration are binding, including profiles, size, opening type, glazing, hardware, anchoring and installation interface.

Which glazing can be used?

The published system range is 54 mm. A specific glass build-up also depends on size, weight, sash dimensions, hardware and structural verification.

Is to RC 2 automatically included?

No. A resistance class only applies to the tested assembly of profiles, hardware, glazing, anchoring and installation. The required class must be specified for the project.

How is the binding whole-window U-factor determined?

From the frame share, Uf value of the actual profile combination, glazing Ug value, glass-edge length, spacer Ψ value and, where applicable, mullions, transoms and special geometry.

From system value to project-specific unit

Enter dimensions. Select the build-up.
Receive a project value.

The configurator connects technical system data with drawings, glazing and a project quotation request.