Technical system data · reviewed 08/2026

Schüco · aluminum windows

AWS 90.SI+
Maximum thermal insulation with great design freedom

The super-insulation window system combines high building-performance requirements with flexible architecture and design solutions. The 90 mm platform is suitable for punched openings, ribbon windows, façade inserts and combinations with Schüco door systems.

  • System-specific performance data
  • Visible revision status
  • For architects and specifiers

Profile section

Explore functional zones
System overview
Profile section of the Schüco AWS 90.SI+ aluminum window system
01

Profile assembly

Published Uf value 0.71 W/(m²K)

Select the three markers to classify the profile assembly, glazing zone, seals and drainage.

Uf value, frame

0.71 W/(m²·K)

Max. Sash height

2,500 mm

sash weight

250 kg

Security

RC 3 up to

Data status

reviewed 08/2026

System values; achievable performance and dimensions depend on opening type, glazing, hardware, profile combination and verified unit configuration.

01 · System performance

Published data in a transparent technical structure.

Every value remains assigned to its technical category, so thermal performance, dimensions, security, comfort and glazing can be reviewed without mixed marketing claims.

System data sheet

Schüco AWS 90.SI+

Revision 08/2026
PropertySystem valueCategory
Insulation & Glazing
Uf value, frameas low as 0.71 W/(m²·K)Insulation & Glazing
Ug value, glazingas low as 0.5 W/(m²·K)Insulation & Glazing
Glass/panel thickness28–68 mmInsulation & Glazing
Glass/panel thickness max.68 mmInsulation & Glazing
Glazing constructionTriple glazingInsulation & Glazing
Sealing planes2Insulation & Glazing
Safety glazingYesInsulation & Glazing
Comfort & Building physics
Sound insulation RwP max.47 dBComfort & Building physics
Air permeabilityClass 4Comfort & Building physics
WatertightnessClass 9AComfort & Building physics
Wind load resistanceClass C5/B5Comfort & Building physics
Operating forcesClass 1Comfort & Building physics
Mechanical strengthClass 4Comfort & Building physics
Operational durabilityClass 3Comfort & Building physics
Hardware corrosion protection classClass 5Comfort & Building physics
Security
Burglary resistanceto RC 3Security
Fall protectionYesSecurity
Safety glazingYesSecurity
Dimensions & Weights
Sash height min.–max.540–2500 mmDimensions & Weights
Sash height max.2500 mmDimensions & Weights
Sash width min.–max.470–1700 mmDimensions & Weights
Sash width max.1700 mmDimensions & Weights
Sash weight max.250 kgDimensions & Weights
Overall frame depth100 mmDimensions & Weights
Sash/frame profile depth100 mmDimensions & Weights
Sightlines
Minimum sightline99 mmSightlines
Outer-frame sightline56 mmSightlines
Sash sightline43 mmSightlines
Mullion sightline86–260 mmSightlines
Maximum mullion sightline260 mmSightlines
Meeting-stile sightline148–163 mmSightlines
Maximum meeting-stile sightline163 mmSightlines
Opening Types & Hardware
TipTronicYesOpening Types & Hardware
TipTronic, inward-openingtilt-and-turn, side-hung, tilt-only, fanlightOpening Types & Hardware
Manual, inward-openingtilt-and-turn, side-hung, tilt-only, double-sash configurations, parallel slide-and-tilt, fanlight and tilt-before-turnOpening Types & Hardware
Opening angle180°Opening Types & Hardware
Concealed hardware systemYesOpening Types & Hardware
Fanlight configurationYesOpening Types & Hardware
Accessibility & Applications
Low threshold ≤ 20 mmYesAccessibility & Applications
Flush thresholdYesAccessibility & Applications
Accessible operating forces under DIN 18040YesAccessibility & Applications
ApplicationsExterior use, residential and commercial constructionAccessibility & Applications
Profile shear bondYesAccessibility & Applications
Finishes & Certification
FinishesPowder coating, anodizing or wet paintFinishes & Certification
CE markingYesFinishes & Certification
CertificateCradle to Cradle SilverFinishes & Certification
Passive house classphCFinishes & Certification
Color-independent performanceYesFinishes & Certification
Planning benefits
Passive housePassive house certification is achievable with a special profile combination.Planning benefits
AvanTec SimplySmartThe concealed hardware system allows large sash weights and an opening angle of 180°.Planning benefits
Accessible solutionsTerrace and balcony doors can be realized in a side-hung, tilt-and-turn and double-sash configurations.Planning benefits
TipTronic SimplySmartSuitable sash profile portfolio for the mechatronic fitting generation.Planning benefits
Facade integrationInsert outer frames with adapter seal compensate for glass thicknesses when integrated into Schüco mullion-transom curtain walls.Planning benefits

Values are taken from the system-specific data already maintained on this website. The binding result is produced from the actual unit configuration.

02 · Profile construction

From profile section to verified project planning.

Profiles, glazing, seals and hardware are treated as one system. This separates published values from the items that require project-specific verification.

01

System platform

100 mm frame depth or profile-dependent construction.

Planning: frame, sash, mullion and meeting stile
02

Glazing

Published range: 28–68 mm.

Planning: build-up, weight, size and spacer
03

Seals and drainage

Air: Class 4 · Water: Class 9A.

Planning: exposure and drainage
04

Hardware and security

Burglary resistance: to RC 3.

Planning: opening type, weight and tested assembly

03 · Interactive tool

Estimate the whole-window U-factor with visible inputs and formula.

The calculator uses the published Uf input for the selected system, the glazing Ug value, the unit geometry and the spacer Ψ value.

Area-weighted preliminary calculation

Enter window data

Live calculation
System and geometry
Glazing and spacer
Preliminary whole-window U-factorSchüco AWS 90.SI+
W/(m²K)
Calculating
Window area Aw
Frame area Af
Glass area Ag
Glass-edge length lg
Formula and calculation

Uw = (Af × Uf + Ag × Ug + lg × Ψg) ÷ Aw

Preliminary planning value. Mullions, transoms, divided lites, special geometry, actual profile combinations and applicable project standards must be included in the binding calculation.

04 · Planning resources

CAD, sections and specifications in one logical area.

Existing resources link directly to the relevant content. CAD details that are not yet public can be requested with the selected system already identified.

PDF

System data

Technical data overview

All currently stored performance values

Current data status · 08/2026
PDF

Downloads

Product brochures and documents

Available manufacturer resources

Website document library
CAD

DWG / DXF

Request a CAD section

Coordinate the appropriate configuration and revision

System preselected
TXT

Specification

Request specification text

System-specific text with project parameters

For architects and specifiers

05 · Planning knowledge

Answers organized around real specification questions.

Frequently asked questions remain readable on the page and are also provided as structured FAQ data.

Which values are binding for AWS 90.SI+?

Only the values of the specifically engineered and verified unit configuration are binding, including profiles, size, opening type, glazing, hardware, anchoring and installation interface.

Which glazing can be used?

The published system range is 28–68 mm. A specific glass build-up also depends on size, weight, sash dimensions, hardware and structural verification.

Is to RC 3 automatically included?

No. A resistance class only applies to the tested assembly of profiles, hardware, glazing, anchoring and installation. The required class must be specified for the project.

How is the binding whole-window U-factor determined?

From the frame share, Uf value of the actual profile combination, glazing Ug value, glass-edge length, spacer Ψ value and, where applicable, mullions, transoms and special geometry.

From system value to project-specific unit

Enter dimensions. Select the build-up.
Receive a project value.

The configurator connects technical system data with drawings, glazing and a project quotation request.